mme gerout vfd 18/BUFPTR,o6/CODE,h12/TERMID zero STATPTR,COURTESY
03 direct access output
04 direct access output, then input
05 user program inquiry to terminal
06 program requests terminal type
17 program requests line disconnect
20 direct access current line status
21 direct access output, then paper tape input
22 accept direct access paper tape input
25 TSS to direct program access switching
26 direct program access to TSS switching
27 generalized direct program access line
switching
30 stop paper tape input
31 quick status mode
32 extended line status
44 extended input line length for DAC programs
45 remote status inquiry for break/disconnect
report
MME GEROUT performs terminal and remote I/O by interfacing with GRTS and the Network Processing Supervisor (NPS).
When issuing MME GEROUT instructions, the same executable code must not be used at both the main level and the courtesy call level. This is necessary because MME GEROUT may be uninhibited, and can be interrupted. The interrupt can be for I/O for this program and can be caused by a previous MME GEROUT with a courtesy call specified in the calling sequence. In this case, the MME GEROUT calling sequence in the main level code is changed.
When control is returned to the interrupt point in the main level code, the MME GEROUT calling sequence does not contain the expected data for continuation of the operation. Instead, it contains data from the last MME GEROUT issued (the one issued in the courtesy call).
Copyright © 2000, Thinkage Ltd.